Difficulties in starting the generator set are common faults that can affect the stability of power supply. Understanding the cause and effectively investigating and resolving it is crucial to ensure the normal operation of the unit.

Electrical system malfunction

Low battery power: Long term use, failure to charge in a timely manner, or leakage of electricity can all lead to low battery power. At startup, the inability to provide sufficient current makes it difficult for the unit to start. It can be checked by measuring the battery voltage. If the voltage is below the normal range, the battery needs to be charged or replaced with a new one.

Motor failure: Internal carbon brush wear and rotor jamming in the starter motor can cause the motor to malfunction. Check for any abnormal noise from the starter motor. If so, disassemble, repair or replace the starter motor.

Generator Set

Loose wiring connections: Loose, oxidized, or broken wiring connecting the battery, starter motor, and control circuit can hinder current transmission. Carefully inspect the connection points of each circuit to ensure a secure connection, and clean, repair, or replace any oxidized or damaged circuits.

Fuel system Problems

Insufficient fuel: The fuel level in the fuel tank is too low to meet the starting requirements. Check the fuel gauge and add fuel that meets the requirements in a timely manner.

Fuel filter blockage: Long term use can cause impurities to clog the fuel filter, affecting fuel flow. Regularly replace the fuel filter to ensure smooth fuel flow.

Fuel injector malfunction: Carbon buildup, blockage, or insufficient injection pressure on the fuel injector can cause uneven or abnormal fuel injection. Clean the fuel injector with professional equipment and replace it if necessary.

Fuel pump malfunction: The fuel pump is unable to establish sufficient pressure to deliver fuel to the engine. Check the working condition of the fuel pump. If there are any problems, repair or replace the fuel pump.

Mechanical malfunction

Poor engine lubrication: Insufficient engine oil, deteriorated engine oil, or clogged oil filters can cause poor engine lubrication and increase starting resistance. Check the oil level and quality, and replace the oil and filter according to regulations.

Poor valve sealing: Poor valve sealing causes cylinder leakage, making it impossible for the engine to compress the air and fuel mixture properly. Check the sealing of the valve, grind or replace the valve components.

Wear of piston rings: Severe wear of piston rings can lead to insufficient compression pressure in the cylinder. By measuring the cylinder pressure, it is determined that if the pressure is too low, the piston ring needs to be replaced.

Environmental factors have an impact

Low temperature environment: Low temperature increases fuel viscosity, reduces battery performance, and increases start-up difficulty. In low temperature environments, preheating devices can be used to preheat the engine and fuel, or to install insulation sleeves on the battery.

High altitude areas: The air in high-altitude areas is thin and the engine intake is insufficient. The engine can be adjusted appropriately, such as increasing the fuel injection amount of the fuel injector, to adapt to high-altitude environments.

The reasons for the difficulty in starting the generator set are complex and require a comprehensive investigation. Daily maintenance and upkeep can reduce the occurrence of faults, ensure that the unit can start normally at any time, and provide reliable guarantee for power supply.


Related Products

Contact us

A: No. 333, Fenglong Road, Yongchuan District, Chongqing, China

T: +86-23-49682222

E: service@googol-power.com   

   Jason.Jiao@googol-power.com 


Contact us

A: No. 333, Fenglong Road, Yongchuan District, Chongqing, China

T: +86-23-49682222

E: service@googol-power.com   

   Jason.Jiao@googol-power.com 


SWEEP

微信掃一掃

[ WeChat Public Number ]

主站蜘蛛池模板: 疏勒县| 哈密市| 紫金县| 阳原县| 奈曼旗| 汉寿县| 育儿| 雅江县| 乐清市| 上饶市| 腾冲县| 满洲里市| 蕲春县| 安阳县| 阜南县| 城市| 南安市| 营山县| 周宁县| 平凉市| 博爱县| 保德县| 绥中县| 宁津县| 新干县| 泰和县| 潜江市| 炉霍县| 张家界市| 蒲城县| 三门峡市| 玛曲县| 嘉黎县| 垦利县| 长宁区| 鹤山市| 聂拉木县| 招远市| 保山市| 宜黄县| 阳新县|